The Design Adjustment Committee of Wilmington, NC, met on Wednesday, July 19, 2023, at 1:30 p.m. in City Council Chambers, Skyline Center. The meeting lasted until 2:31 p.m. and addressed two agenda items: design adjustments for a proposed residential subdivision (Ponderosa Cottages) and a parking lot expansion for Rooms to Go. The committee approved minutes, denied one waiver, granted several others, and conditionally approved a preliminary plan.
Yes, we may short there. So we have five minutes, you know. We'll call this meeting of the design adjustment committee to order. Before we get started, I have an intro to read. The design adjustment committee's purpose is to establish clear and measurable review criteria for the consideration of major deviations from the city's technical standards and specifications manual. The committee does not consider the housing type, cost to the proposed unit, occupants, building material, unit size, number of bedrooms, or the architectural design of the structures. These hearings are quasi judicial evidentiary hearings. All variance requests require a four-fifths vote of the committee to grant the variance. Appeals of design adjustment committee decisions are to the Superior Court. Parties in these cases are entitled to an impartial board. If a board member has a fixed opinion on the matter, a financial interest in the outcome, a close relationship with an affected person, or has had any exparte communication about the matter, please disclose that information to determine if a recusal is necessary. When a witness comes forward to give testimony, please come to the podium, state your name and address to the record, and speak clearly. At this time, staff will administer oath for all individuals who intend to provide witness testimony. If I could have all staff applicants, member of the public, please stand up and raise your right hand. Do you the swear that the testimony you're about to give is the truth, the whole truth, and nothing but the truth? Thank you. The first item on the agenda is the minutes. Everybody had a chance to look over the minutes, and if so. I'd make a motion to approve the minutes. Okay. I'll second. And all in favor of approval? Aye. Aye. Opposed? Okay. All right. The first item on the agenda is the Ponderosa cottages. Is there a staff presentation? Thank you, Chairman. Good afternoon. The following testimony pertains to case DAC-1-723 for approximately 1.966 acres of property located at 525 Ponderosa Lane. The site is located south of Westchester Road and at the terminus of Ponderosa Lane. The applicant is requesting design adjustments for the minimum standards for a local street, street design, and maximum cul-de-sac length, in order to develop a six-lot residential subdivision. The property is currently zoned, R15, moderate density single dwelling district. However, the applicant is seeking a rezoning to R5 CD, medium density mixed residential conditional district. The property is currently developed with a single family detached dwelling. A six-inch water main and eight inch sewer main exist in Westchester Road right-of-way. The site is currently developed with approximately 1,250 square feet of impervious, approximately 1.4% of the site. The proposed impervious will occupy 17,500 square feet of impervious or 20.1% of the site. All proposed streets shall install five foot wide sidewalks on both sides of the street. The applicant proposes no sidewalk on the western side of the proposed extension of Ponderosa Lane and an adjustment is required. All proposed local streets shall be centered in a street cross section within 40 feet of right-of-way. The applicant proposes a street cross section within a 50-foot right-of-way to be centered in the eastern 40 feet, and an adjustment is required. The technical standards further suggests specifies minimum and maximum street design standards, including the tangent length between horizontal curves, shall be a minimum of 100 feet. The applicant proposes a minimum tangent length of 80 feet, and therefore an adjustment is required. Length of a cul-de-sac shall be a maximum of 500 feet. The applicant proposes a maximum length of 650 feet, therefore an adjustment is required. That concludes staff's presentation. Any questions?